How do I eliminate relay noise?

I would like to put an RC network across the relay coil to reduce relay noise, is there any formula to calculate the value of Resistance, Capacitance and their current and voltage values?

How do I link the Profibus I/O to a PLC from my HI 3000 series unit?

Where can I find some information on how to link the Profibus I/O area to the Siemens PLC? In other words, how do I setup and connect the different variables of the controller to the PLC? How do the parameters match the I/O area on the Profibus-DP level? Measured value 1 = address ????? Where can I find a complete list of possible parameters to read and write to the device?

What will be displayed on my Hardy weight controller following a power loss and recovery?

What will be displayed on my Hardy weight controller following a power loss and recovery?

Can I change the "tareval" register though an A-B RIO command in a HI 2151 series unit?

Can I change the "tareval" register though an A-B RIO command in a HI 2151 series unit?

How do I configure the HI 1756WS in a remote rack?

I have two HI 1756WS modules installed in a remote rack connected through ControlNet to the processor. What do I need to do to communicate and configure the modules? Do I need an EDS file for the module for the ControlNet RSNetworks?

Why can't I change set points from my HI 3010 web browser?

I am unable to enter setpoints from my HI 3010 web browser. I can enter them from the front panel and they show up on the configuration web page, although not in real time. The page must be refreshed for the new values to be displayed. How can I enter the setpoints from the web browser?

How can I configure my HI 200DNWM with a blank screen?

When I try to configure my HI 200DNWM through RSNetworks for DeviceNet, the scroll down arrow options shows me a blank screen. What should I do?

What is the minimum time needed for check weighing using a HI 1756WS?

When using the HI 1756WS in a check weighing application, what is the minimum amount of time needed to take a weight measurement?

How do I control a remote display with a HI 2151/30WC?

I am trying to control a remote display using a HI 2151/30WC and I cannot get it to communicate properly. I have the serial port configured as follows: Sercon: Print Sertyp: RS-232 Baud: 9600 Frame: 8-N-1 Format: G----- I have matched these up with the remote display and have wired it as follows: Hardy Txd ------ RLWS Rxd Hardy Gnd ------ RLWS Gnd What am I doing wrong?

Could there be a conflict between M0 and M1 on my HI 1746WS and other modules?

One of my systems utilizes two HI 1746WS modules in a local rack with a 1747-SCNR ControlNet scanner communicating to a remote rack. A different system is using a 1747-SN to Block transfer Analog via MO and MI. Both the HI 1746WS and either coms module would need to utilize MO and MI file of the Local racks memory. Would there be a conflict?