When you use the "BUTTON" on the HI 1756-2WS, do both channels calibrate?

When you use the "BUTTON" on the HI 1756-2WS, does it calibrate both channels simultaneously? How do you calibrate one channel and not the other? When one channel is being calibrated, does the other channel continue to function?

Does the HI 1756WS support user defined data types?

Does the HI 1756WS support user defined data types?

How to perform a traditional calibration via the PLC on a HI 3000 or HI 4000 unit?

How do you perform a traditional calibration (hard cal) via the PLC on a HI 3000 or HI 4000 series units?

Is a RIO block transfer required to receive every channels data on my HI 3030?

Do I need to perform a block transfer on Remote I/O in order to receive every channels data on the HI 3030 unit?

Eddy Probe output measurements

What is the output in mV that an eddy probe gives per mm of displacement?

How does the ROC work in the HI 1756WS?

The ROC is not giving me the product that I'm dispensing (between 400 and 800 kg/hr) after I changed some parameters. Actually it just shows small values below "1" near to "0". The parameters changed in the program were: PARAM_HARDY.ROC_TB: 1)1800, 2)60 PARAM_HARDY.Motion_TOL: 1)1, 2)2, 3)0.1, 4)0.001 PARAM_HARDY.Num_AVGS: 10 The changes made to these parameters did not make a difference in the rate reported. How does the ROC work in the HI 1756WS? Why didn't the changes to these parameters take effect?

How do you view multiple 3000 Series units connected via the Ethernet browser?

If I am connected to the Series 3000 controller (via the Ethernet browser) that is also connected to another Series 3000 via DEVICENET, can I look through the first Series 3000 on my PC to see what's going on in the second Series 3000?

What would be the suggested logic for RIO communication on my HI 3000 series unit?

What would be the suggested logic for communication using discrete and block transfer? If I use discrete, what data and in what order can I access it? If it is by block transfers what would be the configuration and length of them so as the order of the data showed in the data table in which I will read?

What is the operational temperature range for Hardy Junction Boxes?

What is the operational (specified) temperature range for the HI 215JB standard Hardy junction box and for the HI 215IT Integrated Technician junction box?

Can I connect a remote display to the HI 3010 serial port?

Can I connect a remote display to the HI 3010 serial port?