Why does my HI 1756WS get a -8 error when using the HI 215IT junction box?

I am using a HI 1756WS with a HI 215IT junction box and 2 Load Cells. When I try to do a hard calibration an error is shown (-8 = "HARCALFAILSCOUNTS"). If I connect the load cell to the HI 1756WS directly (bypassing the junction box) it works with no error. Why does my HI 1756WS get a -8 error when using the HI 215IT junction box?

What is the temperature range of the Advantage type load cells?

What is the temperature range of the Hardy Advantage Series load cells?

Why does the HI WS100 software lock up on my HI 1746WS?

When using the HI WS100 software I can communicate with my HI 1746WS module using the DF1 connection, but when I switch to the Ethernet connection the HI WS100 software locks up. Are there any specific RSLinx/Processor settings I need to change?

What sequence should I wire my load cells into the summing junction box?

We use a Hardy Instrument and summing junction box in our plant. Does it matter what sequence the load cells are wired into the summing box?

Does the HI 3300 Tension Controller have C2® capabilities?

Does the HI 3300 Tension Controller have Second Generation Calibration C2® capability?

Is there a relay option for the HI 2151/30WC?

We would like to use relays with our HI 2151/30WC. There is a J4 Opt Relays female port, but no male connector. Can we use those relays or do we have to purchase a relay option? What part number should we order? Does it require a new secure memory module (SMM)? How do we install it?

Does the HI 2110WI replace the HI 2151/20WC or HI 2151/30WC?

We are upgrading our facility and want to replace existing HI 2151/20WC and HI 2151/30WC controllers. The contractor recommends replacement of these units with new HI 2110WI units. What is the value added? Why not use the existing units? Will the HI 2110WI's be drop-in replacements?

How many HI 1756WS modules can I install in a ControLogix chassis?

How many HI 1756WS and/or HI 1756-2WS modules can I install in a ControLogix chassis?

What happened to our Hardy Instrument after we lost power?

Last week during severe weather we lost power in the plant. After power was restored we had an issue with one of our Hardy Instruments. What could have happened to our Hardy Instrument after losing power?

Can I directly enter calibration values in the HI 2151/30WC?

I would like to be able to do a very rough calibration on my HI 2151/30WC without emptying the hopper on the load cell. This is useful in several instances such as when an instrument is replaced, and the hopper is full. We need a very rough calibration to allow us to avoid our interlocks and run enough to get empty and do a real calibration. I seem to remember a way to put "fake" zero and span counts, but I can't find anything in the manual. Can I get a procedure for directly entering calibration values in my HI 2151/30WC?