What is the response time of a HI 3000 series controller?

If I am using a 4 channel HI 3030 weight controller for a check weighing application, how long does the item being weighed need to be on the scale in order to get a good weight reading ?

What is the temperature range for the C2® chip?

What is the acceptable temperature range for the C2® chip located inside the load cell or at the end of the cable?

What information can I access (read/write) through the DeviceNet on a 3000 or 4000 series unit?

What information can I access (read/write) through the DeviceNet network in my HI 3010, HI 3030, HI 3300, HI 3600, HI 4050 or my HI 4060?

How do I clear the red fault LED on my HI 200DNWM?

How do I clear the red fault LED on my HI 200DNWM?

When welding near load cells, what precautions need to be followed?

What precautions need followed when welding on vessels with load cells?

What are the power requirements for the HI 3000 series?

What are the power requirements for the HI 3010,  or the HI 3030?

Is the HI 215IT summing board compatible with all Hardy Instruments?

We are not getting a reading from the HI 215IT junction box. The HI 215IT is connected to a HI 1771-XX-RT and from there it is connected to a HI 1771WS module using the HI 1771-XX-C6 cable. Is the HI 215IT summing board compatible with all Hardy Instruments?

How can I tell if my load cell is good without using Integrated Technician?

I am using older load cells from Hardy Process Solutions (or from another company) and I want to make sure they are functioning properly before I use them in another application. I don't have the Hardy feature "Integrated Technician" in my junction box or controller, so I checked the installation/troubleshooting guide which says to check the resistance between the signal wires and the excitation wires and the resistance of each should be around 350 ohms. Well, the resistance between the signal wires on all 8 load cells was right at 350 ohms, but the resistance between the excitation wires on all 8 load cells was around 387 ohms. So, are all of these load cells bad, or is it ok for the excitation resistance to be 387 ohms?

Using a 4-Scale HI 3030, can I see individual load cell MV readings with IT?

Can I see individual load cell MV readings with IT on a HI 3030-4S (four scale option)?

Do I need to use the HI WS100 Configuration Software?

I just purchased new Hardy load cells and an HI 1746WS module. The manual that came with the module says that the software is optional. If the software is optional how does the PLC communicate with the module? Do I need to use the HI WS100 Configuration Software to communicate with my HI 1746WS?