Knowledgebase

Filter Filter button
Results: 41 - 50 of 540

Categories

When do I use zero or tare?

When do I use ZERO or TARE on my Hardy unit?

Can I use the HI 4060 rate controller On/Off relay to activate a separate vibrator motor?

I will be operating a variable speed screw feeder using the 4-20 ma output from the Hardy Rate controller and I need to activate a separate hopper vibrator motor whenever the screw feeder motor operates. Does the ON/OFF output relay contact on the back of the Hardy Rate controller correspond to the 4-20 ma output in any way, or is this relay just to indicate when the Hardy Rate is actually turned on and off? I do not want the vibrator running unless the screw is actually feeding, so I need a contact that closes only when the Hardy Rate controller is calling for product to be discharged.

How can I transfer product from a storage tank to multiple day tanks?

What technique can be used to transfer product from a storage tank to multiple day tanks based upon need?

Can I upgrade my HI 3010 with an -SD option?

Can I upgrade my HI 3010 with a -SD option? If yes what do I need to order and what is the procedure to install the -SD card?

How do I calculate the system total full scale output sensitivity?

How do I calculate my weighing system total full scale output sensitivity?

What is the difference between high and low calibration?

What is the difference between high and low calibration?

Why doesn't my HI 3010 register all of the fill material on the scale?

Why doesn't my HI 3010 register all of the fill material on the scale? If a fill cycle is started, and for some reason weight is applied to the scale before the OK To Fill Signal is given, when the OK To Fill signal goes true the scale is zeroed even though Use Auto Zero is off. Consequently, discharge is over when the scale reaches its Auto Zero point. For example, I have the scale calibrated for 0 - 100 lb. I press start and "Waiting On" is displayed. If during this time I add 50 lb to the scale, it will now read 50/50. I then apply the OK to Fill signal and the display reads 0/50. I then add 50 lb to the scale and it reads 50/100 and awaiting OK To discharge comes on. I remove 50 lb from the scale and it reads 0/50. There is still 50 lb on the scale.

Does the HI 3010 have a RS232 serial port?

Does the HI 3010 have a RS232 serial port?

Serial communication setup for HI 2151/30WC or HI 2160RC

How do I get the serial communications to work between my PC and HI 2151/30WC or HI 2160RC?

Should I repair or replace the keypad on my HI 2151/30WC or HI 2110WI?

How do I determine if my HI 2151/30WC or HI 2110WI keypad needs to be replaced? How do I troubleshoot the keypad, and can I order a new keypad interface assembly?