Results: 261 - 270 of 540

Categories

How do I zero out my instrument?

How do I zero out my HI 2110WI, HI 2151/30WC or my older HI 2151/20WC?

How do I make a load cell simulator?

I have a controller set up in my office but no load cells and I would like to test my PLC programming. Can I use a trim pot to simulate the load cells? If so, how can this be done?

Do I need an IT Junction Box to use smart diagnostics with a HI 3010 controller?

Do I need an IT Junction Box to use smart diagnostics with a HI 3010 controller?

When should I use the trim pots on the summing cards?

What are trim pots for on the summing cards? When are they needed?

How do I map data from one HI 3000 unit to another HI 3000?

I am using two HI 3030's, one with four channels, one with two. I have one ControlNet card in the 4 channel configuration and I am only going to read and send the gross weight and net weight to the ControLogix. In the dual channel unit I need to map these parameters and transfer them through a HardyLink (Ethernet) network to the four channel unit with the ControlNet card. How do I map weight data from one unit to another unit that has the ControlNet interface?

How do I eliminate relay noise?

I would like to put an RC network across the relay coil to reduce relay noise, is there any formula to calculate the value of Resistance, Capacitance and their current and voltage values?

How do I link the Profibus I/O to a PLC from my HI 3000 series unit?

Where can I find some information on how to link the Profibus I/O area to the Siemens PLC? In other words, how do I setup and connect the different variables of the controller to the PLC? How do the parameters match the I/O area on the Profibus-DP level? Measured value 1 = address ????? Where can I find a complete list of possible parameters to read and write to the device?

What will be displayed on my Hardy weight controller following a power loss and recovery?

What will be displayed on my Hardy weight controller following a power loss and recovery?

Can I change the "tareval" register though an A-B RIO command in a HI 2151 series unit?

Can I change the "tareval" register though an A-B RIO command in a HI 2151 series unit?

Why can't I change set points from my HI 3010 web browser?

I am unable to enter setpoints from my HI 3010 web browser. I can enter them from the front panel and they show up on the configuration web page, although not in real time. The page must be refreshed for the new values to be displayed. How can I enter the setpoints from the web browser?