Can I communicate with a PC using visual basic and a HI 3000 series controller?

I want to develop an application in Visual Basic to communicate with my HI 3000 series controller via a PC. Can I use either the -MB or the HI 3000-OPC options?

What are the sense wires for?

I am trying to install a Hardy Instrument and there are 9 wires: 2 for signal, 2 for excitation, 2 for C2®, 2 for sense and a shield wire. What are the 2 sense wires for?

How do I map values using DeviceNet?

I'm trying to map values using DeviceNet and an HI 4060. The HI 4060 is at address 10 and shows as connected on the DeviceNet network. I have set the HI 4060 for slave mode and I am polling it with a 1756-DNB/A. I want to map the Net Weights and control to the DeviceNet scanner in the PLC. I also want to set the rate set points from the PLC. At this point I don't care about any other values. How do I set the mapping in the rate controller for this?

Where I can find a list of mapping symbols for the HI 3000 and HI 4000 units?

Where I can find a complete list of the HI3000 or HI 4000 internal mapping symbols, such as HFO, HFI, HDI, HDO, etc?

Can I connect separate scales to a HI 3030?

I have an application to replace a scale controller that controls two scales. I would like to use a HI 3030 on DeviceNet back to a A-B SLC 5/04. Can I connect two separate scales to a HI 3030 or do I need two HI 3030's? I want to be able to control the scales individually and would also like to do a traditional calibration from each scale.

Why would my HI 2151/30WC lock up and fail to communicate?

Our application involves polling the HI 2151/30WC every 32 seconds for net weight. My HI 2151/30WC locks up and fails to communicate. What could be the cause?

What is the maximum load cell cable length?

What is the longest length cable I can have on a load cell and still get a full range reading? Does this have to be a manufacturer supplied cable?

How many load cells can I use with my HI 3030 or HI 3010?

How many load cells can a HI 3010 or HI 3030 power? Will C2® work with more than 4 load sensors?

How do I perform a Parameter Dump Read/Write on the HI 3000 or 4000 series?

What is the procedure for performing a Parameter Dump Read/Write on my Hardy HI 3000 series or HI 4050 controller?

Where can I find an example of explicit messaging for the HI 3030?

Where can I find an example of explicit messaging to the HI 3030, and all the instance codes for the parameters?