How many words can be mapped into my HI 3000 series unit interfaced to ControlLogix?

I have four Hardy HI 3000 series units on a system.  They are connected together over Ethernet with one being connected to a ControlLogix processor over ControlNet. I am sending information to the one HI 3000 series connected to the ControlLogix processor and seem to encounter a limit of 64 words into this HI 3000. Is there a word limit? If there is a limit, what is the exact number of words I can map into the one 3000 series connected to the ControlLogix processor?

Do I need to use a UPS on my Hardy Controller?

Does Hardy suggest using a UPS on the input? What does "computer clean power" mean?

How do I adjust the response time of my Hardy controller?

What parameter modifies the response time? It is taking too long to see a stable weight reading on my controller.

What is a 767 error code?

What is a 767 error code?

What sequence should I wire my load cells into the summing junction box?

We use a Hardy Instrument and summing junction box in our plant. Does it matter what sequence the load cells are wired into the summing box?

Is there a relay option for the HI 2151/30WC?

We would like to use relays with our HI 2151/30WC. There is a J4 Opt Relays female port, but no male connector. Can we use those relays or do we have to purchase a relay option? What part number should we order? Does it require a new secure memory module (SMM)? How do we install it?

Does the HI 2110WI replace the HI 2151/20WC or HI 2151/30WC?

We are upgrading our facility and want to replace existing HI 2151/20WC and HI 2151/30WC controllers. The contractor recommends replacement of these units with new HI 2110WI units. What is the value added? Why not use the existing units? Will the HI 2110WI's be drop-in replacements?

What happened to our Hardy Instrument after we lost power?

Last week during severe weather we lost power in the plant. After power was restored we had an issue with one of our Hardy Instruments. What could have happened to our Hardy Instrument after losing power?

Can I directly enter calibration values in the HI 2151/30WC?

I would like to be able to do a very rough calibration on my HI 2151/30WC without emptying the hopper on the load cell. This is useful in several instances such as when an instrument is replaced, and the hopper is full. We need a very rough calibration to allow us to avoid our interlocks and run enough to get empty and do a real calibration. I seem to remember a way to put "fake" zero and span counts, but I can't find anything in the manual. Can I get a procedure for directly entering calibration values in my HI 2151/30WC?

What is the color code between the junction box and controller using Hardy C2 cable?

What is the color code between the junction box and controller using Hardy C2 cable?