Why am I getting an error with message command to zero?

I have a message command to zero the HI 1756WS module. When activated I get the following error: Error Processing Connection Related Service. The message parameters are as follows: Message Type: CPI Generic Service Type: Custom Source Element: HardyZero Source Length: 8 Destination: HardyZero Service Code: 4c Class: 4 Instance: 254 Attribute: 0 The comm path is set to the Hardy 1756 Module in slot 4 Under the Tag Folder the tag name is Hardy_ZeroCmdMsg Why am I getting an error with message command to zero?

What is the maximum load cell cable length?

What is the longest length cable I can have on a load cell and still get a full range reading? Does this have to be a manufacturer supplied cable?

Are the Advantage load cells compensated for static or thermal effects?

Are Hardy's Advantage load cells compensated for static effects or thermal effects? How is this compensation accomplished? Is each sensor tested under different thermal conditions or are representative units from a lot used to predict what compensation is appropriate for that lot?

How many load cells can I use with my HI 3030 or HI 3010?

How many load cells can a HI 3010 or HI 3030 power? Will C2® work with more than 4 load sensors?

How do I perform a Parameter Dump Read/Write on the HI 3000 or 4000 series?

What is the procedure for performing a Parameter Dump Read/Write on my Hardy HI 3000 series or HI 4050 controller?

Where can I find an example of explicit messaging for the HI 3030?

Where can I find an example of explicit messaging to the HI 3030, and all the instance codes for the parameters?

Why is my HI 1746WS getting an Excitation Error and no weight indication?

My HI 1746WS is showing an excitation error bit equal to one and the weight is showing 0.000kg with no movement either direction of zero. How is this problem corrected or how do we troubleshoot?

Should I use a pneumatic brake or an electric brake in my Tension Control application?

Should I use a pneumatic brake or an electric brake in my Tension Control application?

Do you have programming examples from PLC-5 to HI 200DNWM?

Do you have any programming examples from PLC-5 to HI 200DNWM? Getting the weight into the PLC? Calibration from the PLC-5?

What is zero tracking?

What is zero tracking?