Why is the analog output from my HI 2151/30WC or HI 2110 WI unstable?

We have installed a 4-20ma loop to a SLC500 from an analog option card. After completing the calibration the loop gives a reading that is oscillating by +/-30kg when reading a weight of 90kg, but the HI 2151/30WC display is stable. We added some filtering on the PLC input but are wondering why the 4-20ma analog output signal is so unstable?

What are the display options for my HI 2151/30WC or HI 2110WI?

What is included with the different display options for the HI 2151/30WC or the HI 2110WI? Is the Display/Blind Remote (0535-0461-02) obsolete and how can I recover?

Why does my HI 2151/30WC have a blank display?

Why does my HI 2110WI or HI 2151/30WC have a blank display?

Why can't I enter the calibration menu on my HI 2110WI or HI 2151/30WC?

When I try to enter the calibration menu on my HI 2110WI or HI 2151/30WC it displays "Sec CD". I toggle the external switch "Cal" and nothing happens. This problem only happens when I have the secure module memory inserted in the rear of the controller. When the memory module is removed I can enter the calibration. Apparently the controller isn't seeing the configuration of the dip switch because when I review the "self test" the Dip 1 shows "0" no matter the position of the dip switch.

How many relay outputs does the HI 3010 have, and at what voltage?

How many relay outputs does the HI 3010 filler/dispenser have, and at what voltage?

What is a force refill on the Hardy Rate controller?

What is a force refill on my Hardy Process Solutions rate controllers?  

Will an incorrect graduation size setting give an Error 1?

What graduation sizes are available on the HI 2151/30WC? Why am I getting an Err 1?

What are the differences between the HI 2151/20WC and the HI 2151/30WC?

What are the differences between the HI 2151/20WC and the HI 2151/30WC?

How do I enter Self-Test on my HI 2110WI or HI 2151/30WC?

How do I enter Self-Test on my HI 2110WI or HI 2151/30WC?

Does "scale capacity" set the upper range on my HI 2151/30 and HI 2151/20?

I have an HI 2151/30WC and an old obsolete HI 2151/20WC. Does "scale capacity" set the upper range of what will be sent to my DCS system (Fisher Provox). The signal gets to the DCS system thru an "EIC" card, we do not use the analog output.