Vous n'avez aucun article dans votre panier.

Nouvelles gammes de batterie HIDS !

Cliquez ici pour en savoir plus !
Support: 858-292-2710

knowledgebase

Filtre Filter button
Results: 511 - 520 of 828

Catégories

Do I have direct M File mapping in my HI 1746WS?

How can I tell if I have the direct M File mapping available to use in my HI 1746WS module?

Why must the Sense Lines be used with C2® Second Generation Calibration?

Why must the Sense Lines be used with C2® Second Generation Calibration load points?

Can the Hardy rate controller's remote function pause option be used as an interlock?

Can the Hardy rate controller remote function pause option be used as an interlock to prevent activation of the feeder before the process is ready? If so, can the switch between Pause and Ground safely be maintained (closed) until the process is ready?

How can I clear the ERREXC error from my HI 2151/30WC?

I am getting an ERREXC error on my HI 2151/30WC. What does that mean and how can I clear the error?

Why is the analog output from my HI 2151/30WC or HI 2110 WI unstable?

We have installed a 4-20ma loop to a SLC500 from an analog option card. After completing the calibration the loop gives a reading that is oscillating by +/-30kg when reading a weight of 90kg, but the HI 2151/30WC display is stable. We added some filtering on the PLC input but are wondering why the 4-20ma analog output signal is so unstable?

What are the display options for my HI 2151/30WC or HI 2110WI?

What is included with the different display options for the HI 2151/30WC or the HI 2110WI? Is the Display/Blind Remote (0535-0461-02) obsolete and how can I recover?

Why does my HI 2151/30WC have a blank display?

Why does my HI 2110WI or HI 2151/30WC have a blank display?

Why can't I enter the calibration menu on my HI 2110WI or HI 2151/30WC?

When I try to enter the calibration menu on my HI 2110WI or HI 2151/30WC it displays "Sec CD". I toggle the external switch "Cal" and nothing happens. This problem only happens when I have the secure module memory inserted in the rear of the controller. When the memory module is removed I can enter the calibration. Apparently the controller isn't seeing the configuration of the dip switch because when I review the "self test" the Dip 1 shows "0" no matter the position of the dip switch.

How many relay outputs does the HI 3010 have, and at what voltage?

How many relay outputs does the HI 3010 filler/dispenser have, and at what voltage?

Do you have a startup check list for a HI 1746WS?

I'm installing a HI 1746WS. Do you have a quick check list to help with startup?