Click Here to Learn More!In Tension Control applications, load cells often see overloads that far exceed their specified rated capacities. These overloads are very common and are due to:
- Inertia of the moving rolls
- High line speeds
- Variations in force for the product being conveyed
- Rapid line accelerations
For this reason, calibration in many web tension applications takes place time and time again as the occurrences of overload require constant re-calibration of the load cell based systems.
Because of its mechanical design, an LVDT provides a much higher overload rating than that of typical strain-gage type load cells. While LVDT's do not provide the level of precision of strain-gage load cells, they do provide greater protection from damage due to overloads and are appropriate for this type of application.