You have no items in your shopping cart.

New HIDS Drum Scales!

Click Here to Learn More!
Support: 858-292-2710

Can I initiate all commands via RIO on my HI 2160RC or HI 4060?

Last updated 05/12/2014 10:54 AM

Question

What commands can be given from the front panel of the HI 2160 RC rate controller that cannot be done via Remote I/O?

Answer

The following commands cannot be initiated with Remote I/O, but can be initiated from the HI 2160 RC or HI 4060 front panel keypad:

1. Set Time
2. Set Date
3. Security Code Setup
4. Only the HI 2160RC - Auto Refill ON / OFF or clear totalizer can be set but should never be changed during a batch or run. This will corrupt the totalizer.  No problems using the HI 4060.

5. HI2160RC Self test information is not accessible.