The Hardy OneMount™ with Advantage® beam sensors provide extraordinary flexibility and durability for industrial environments. OneMount load point systems are specifically built to save customers time and money during installation, calibration, and maintenance.
Each feature of the load point was intentionally designed based on nearly 100 years of process weighing experience, creating a best-in-class measurement system for small hoppers, tank weighing systems, bagging machines, and other low-capacity industrial applications.
Accuracy
- Self-centering rocker design maintains alignment under substantial shear forces
- Precision sensor (combined error 0.02% rated output) from 22 lbs – 550 lbs
- Optional Dynamic Stabilization Rods reduce vibration noise on the sensor for better resolution
Safety
- Best-in-class liftoff and side force ratings for safety under stress
- True glass-to-metal hermetically sealed sensors deliver the ultimate washdown protection (IP68/IP69K)
- C2® cloud-based calibration reduces the risk of accidents or contamination from test weights
Easy Installation
- Built to carry the full rated capacity without the load cell installed,eliminating the need for expensive dummy load cells and welding fixtures
- Once the mount is installed, the load cell slides into place. With minimal tank jacking (1/8”), the two spacers are removed for a live load point
- 360° checking mechanism means load points can be installed in any direction
- C2® weightless calibration for fast startup in high capacity installations with a Hardy weight controller or weight processor
Easy Maintenance
- Replace load cells with minimal tank jacking (1/8”).
- Matched mV/V/ohm load cells are easy to replace without recalibration
User Benefits
- OEE improvement from consistent, accurate performance, and reduced installation and maintenance time
- Reduced capital investment and labor typically associated with dummy load cells and welding fixtures
- Reduced complexity of system selection and installation from a single, universal design
SPECIFICATIONS HI HBB01 Load Sensor
- Maximum Capacity (Emax) lbs: 22 / 44 / 110 / 220 / 440 / 550
- Max number verification intervals nmax: 3000
- Min load cell verification interval vmin: Emax / 11000
- Combined Error: %RO ± 0.0200
- Non- Linearity: %RO ± 0.0166
- Hysteresis: %RO ± 0.0166
- Creep error (30 Minutes) / DR: %RO ± 0.0166
- Temperature effect on min dead load output: %RO/10°C ± 0.0140
- Temperature effect on sensitivity: %RO/10°C ± 0.0100
- Non-Repeatability: Not Specified
- Rated Output (RO): mV/V 2 ± 0.1%
- Calibration in mV/V/Ω: Matched
- Zero Balance: %RO ± 5
- Exictation Voltage V: 5-15
- Input Resistance Ω: 380 ± 10
- Output Resistance Ω: 350 ± 3
- Insulation resistance (100VDC): MΩ ≥ 5000
- Load Cell Safe Load Limit %Emax: 200
- Load Cell Ultimate Load Limit %Emax: 300
- Load Cell Safe Side Load %Emax: 100
- Maximum Platform Size: N/A
- Compensated Temperature Range °C: -10 …+40
- Operating Temperature Range °C: -40…+80
- Load Cell Material Stainless Steel 17-4PH (1.4548)
- Sealing: Complete Hermetic Sealing, Glass to Metal Header
- Protection according to EN 60 529: IP68 (up to 2m water depth)
- Cable Length: 10 ft
- Hazardous Certification: S Class 1,2,3 Div 1
HI ONEMT OneMount™
- Capacity lb: 22lb - 550lb
- Rated Liftoff Force lb: 225
- Rated Overload lb: 1100
- Rated Side Force lb: 550
- Weight Excluding Load Cell lbs: 4
- Material Metallurgy: Electropolished Stainless Steel / Stainless Steel / Plated Steel
- Levelling Required: 0.4/100 (legal for trade) / 0.8/100 (general applications)
Specifications are subject to change without notice