How do I set the number of decimal points on my HI 1746WS?

I want one decimal point on my HI 1746WS and I want to read it as an integer. Using RSLogix 500 where do I set this?

How do I configure the HI 1746WS software for the remote chassis?

How do I configure the HI WS100 software to work with a HI 1746WS located in a remote chassis?

Can I measure multiple load cells or scales with one controller?

We want to install 6 load cells and measure each load cell individually. The sales literature for one of the Hardy models states that it accepts a single load cell or the sum of several load cells. Does this mean I can measure multiple scales with one load cell per scale with a single controller?

How can I prevent my weigh vessel from slipping off Advantage load cell mounts?

My weight readings were bad and I found the vessel had slipped off the Advantage load cell mounts. What can I do to prevent this from happening again?

Do I need to connect the load cell shield wire?

Do I need to connect the load cell shield wire? Where is the best place to connect it?

Using Profibus, how do blocks get mapped into Siemens PLC?

Using the HI 2151/30 unit, How do Hardy Blocks get mapped into Siemens addresses using Step 7 and Hardy GSD file (i.e. Hardy 32W I/O, 16 W blocks; 16W I/O, 8W blocks)? Siemen's allocates addresses based on Hardy I/O selection above; how do these addresses map into Hardy blocks?

How can I get my HI 2151/30WC in continuous print mode?

I am interfacing to a HI 2151/30WC via the serial port, with the intent of having the serial port in continuous output mode. I read the HI 2151/30WC manual and can't find the serial string format for this mode (there is quite a bit of information on the command format, but not on the continuous output mode). How can I get my HI 2151/30WC in continuous print mode?

How do I see the live weight and the IT values with the HI 1756WS?

How do I see the live weight and the Integrated Technician values with my HI 1756WS module?

How can I calibrate in KG using C2® calibration?

I can't get my  HI 2151/30WC, HI 2110WI,  HI 1771WS or HI 2160RCplus to read weight in KG. How can I calibrate in KG using C2® calibration?

How do I determine if my load cells are reacting correctly to weight?

How do I determine if my load cells are reacting correctly to weight?