Is the HI 215IT summing board compatible with all Hardy Instruments?

We are not getting a reading from the HI 215IT junction box. The HI 215IT is connected to a HI 1771-XX-RT and from there it is connected to a HI 1771WS module using the HI 1771-XX-C6 cable. Is the HI 215IT summing board compatible with all Hardy Instruments?

How can I tell if my load cell is good without using Integrated Technician?

I am using older load cells from Hardy Process Solutions (or from another company) and I want to make sure they are functioning properly before I use them in another application. I don't have the Hardy feature "Integrated Technician" in my junction box or controller, so I checked the installation/troubleshooting guide which says to check the resistance between the signal wires and the excitation wires and the resistance of each should be around 350 ohms. Well, the resistance between the signal wires on all 8 load cells was right at 350 ohms, but the resistance between the excitation wires on all 8 load cells was around 387 ohms. So, are all of these load cells bad, or is it ok for the excitation resistance to be 387 ohms?

Using a 4-Scale HI 3030, can I see individual load cell MV readings with IT?

Can I see individual load cell MV readings with IT on a HI 3030-4S (four scale option)?

Do you have menu trees for the Filler, Dispenser and IBC controller?

Do you have menu trees for the HI 3010 Filler, Dispenser and IBC controller that would make setup easier?

Where in the computer do you install the EDS file?

Where in the computer do you install the EDS file?

What is the difference in the 3 mapping areas where motion status can be read?

What is the difference in the three mapping areas where the HI 3030 4-scale motion status can be read, Status word bit 6, Command status, and the Boolean words HI2.12-HI2.15 for each scale?

Why are 127 words too large for the HI 3000 series ControlNet configuration?

I am using a HI 3000 series instrument. When entering the size parameter under ControlNet configuration it says size: 127 is to large. Why?

What is the difference between analog and digital communications?

What are the main differences between using analog or digital communications? Why is digital communications considered a better form of communications?

Can my HI 3010 do an auto print at the end of a cycle?

I would like my HI 3010 to do a print at the end of each fill cycle, but would rather not rely on pressing the print button each time. Can the unit be set up to do the print automatically?

What is the return to zero function and how is it used?

What is the return to zero function and how is it used?