Sie haben keine Artikel in Ihrem Warenkorb.

Neue HIDS-Trommel-Skalen!

Klicken Sie hier, um mehr zu erfahren!
HIRCDM - Dynamic Mounts

HIRCDM - Dynamic Mounts

HIRCDM Dynamic Mounts are rocker load point systems specially designed for hopper and tank weighing. Easy to install by bolting or welding, they have a low profile, and provide lift off protection. Each rocker load point consists of either alloy or stainless steel mounting hardware and a stainless steel mV/V & mV/V/ohm matched load cell sensor with true hermetic sealing, Hardy’s exclusive C2® calibration, a ¼ NPT conduit adapter and 30 feet of cable.

Or call 858.278.2900 for assistance

Each assembly provides built-in checking with check links, lift off protection and is specifically designed to eliminate the effects of unwanted forces to provide exceptional accuracy. A grounding strap, fixed color code wiring label and installation manual are provided with each load point. The HIRCH04 ADVANTAGE® load cell sensor has an IP rating of IP68/IP69K and comes in the following standard capacities: 16.5 to 50Klbs. The HIRCH03 sensor is certified to NTEP Class III and is available in 66 and 88Klbs capacities.

Accuracy

  • Self-centering rocker design maintains alignment under shear forces
  • Precision sensor (combined error 0.02%-0.05% rated output) up to 88Klbs

Safety

  • Integral checklinks provide safety against sheer forces even with substantial vibration
  • True glass-to-metal hermetic sealing delivers the ultimate protection to sensors during washdown (IP68/IP69K)
  • C2® calibration reduces the risk of accidents or contamination from test weights 

Easy Maintainence 

  • Replace load cells with minimal tank jacking.  Removable load cups enable sensors to slide in and out
  • Matched mV/V/ohm load cells are easy to replace without recalibration
  • C2® calibration is quicker and easier than traditional load cell calibration

Key Features

  • Mounts are available in stainless or alloy steel to deliver the best combination of price and performance 
  • FM Certified load cell for intrinsically safe applications

HIRCDM Mounts

Mount Part Number L x W x H Material Weight
HIRCDM-AS-16.5KLB-50KLB 8" x 6" x 5.1" Zinc Plated 30 Lbs.
HIRCDM-AS-66KLB 11.8" x 6.1" x 9.8" Zinc Plated 55 Lbs.
HIRCDM-AS-88KLB 11.8" x 6.1" x 9.8" Zinc Plated 55 Lbs.
HIRCDM-SS-16.5KLB-50KLB 8" x 6" x 5.1" 304SS 30 Lbs.
HIRCDM-SS-66KLB 11.8" x 6.1" x 9.8" 304SS 55 Lbs.
HIRCDM-SS-88KLB 11.8" x 6.1" x 9.8" 304SS 55 Lbs.

Load Cell MAXIMUM CAPACITY (Emax) IN Klbs: 16.5K / 33K / 50K / 66K / 88K 

  • Maximum number verification intervals (nmax): 3,000
  • Minimum load cell vertifcation inteval (vmin): Emax/15,000
  • Combined Error (%RO): ± 0.0200
  • Non-Linearity (%RO): ± 0.01666
  • Hysteresis (%RO): ± 0.01666
  • Creep Error (30 minutes) /DR (%RO): ± 0.01666
  • Temperature effect on min dead load output (%RO) /10°C: ± 0.0093
  • Temperature effect on sensitivity %RO/10°C: ± 0.0100
  • Rated Output (%RO) mV/V: 2 ± 0.1
  • Calibration in mV/VO: Matched
  • Zero Balance (%RO): <± 5
  • Excitation Voltage (V): 5-15
  • Input Resistance(W): 1150 ± 50
  • Output Resistance(W): 1000 ± 2
  • Insulation Resistance(100VDC) (MW): ≥5000
  • Excitation voltage: 5-15 VDC
  • Load Cell Safe Load Limit(% Emax): 200
  • Load Cell Ultimate Load Limit (% Emax): 300
  • Load Cell Safe Load Limit (% Emax): N/A
  • Minimum load cell verification interval (vmin): N/A

Environmental Specifications

  • Temperature effect on min dead load output (%RO) /10°C: ± 0.0400
  • Temperature effect on sensitivity %RO/10°C: ± 0.0200
  • Load Sensor Material: Stainless Steel 17-4 PH (1.4548)
  • Sealing: Complete Hermetic Sealing -- Glass to Metal Header
  • Protection According to EN 60529: IP68 (up to 2m water depth/IP69K
  • Cable Length: 30 ft
  • Hazardous Certification: IS Class 1,2,3 Div 1, NI Class 1,2,3 Div 2
  • Legal for Trade: NTEP (LPRC03 only)

All specifications are subject to change without notice.

Capacity

Mount Finish

Model # - HIRCDM copy
Or call 858.278.2900 for assistance

The Hardy Process Toolbox is a set of productivity tools that support industrial weighing functions. Each tool saves time, increases accuracy, improves efficiency, or reduces risk in process weighing applications, including C2® electronic calibration, and Integrated Technician® to name just a few.

Hardy load cells support the following Hardy Process Toolbox functions when coupled with a Hardy Instrument and Hardy C2® cable.

C2® (or eCAL) Electronic Calibration

The Hardy C2® (or eCAL as it is known in China) core feature provides quick and easy electronic calibration of a weighing system without the need for heavy test weights.

INTEGRATED TECHNICIAN® Operator Diagnostics

Hardy's INTEGRATED TECHNICIAN (IT) core feature helps you troubleshoot your weighing system and diagnose problems from the front of the instrument or via the PLC. These tests display system weights, voltages, and pass/fail displays to help isolate a problem to the instrument, cabling, or sensors, helping to reduce maintenance costs.

Certifications

Datasheets

Drawings