HI6800 - Weight Controller

HI6800 - Weight Controller

The HI 6800 instruments are weight controllers ideal for a wide variety of weight-based applications. The HI6800 features a dual-core processor and combines direct process control with fast, accurate and stable weight data essential to profitable manufacturing operations.

Or call 858.278.2900 for assistance

Designed to address the needs of both highly integrated and stand-alone industrial weighing applications, the HI 6800 Series serves as an all-in-one weight controller.The Model HI6800 is designed for weight-based control of applications such as level monitoring, set-point control, static checkweighing, and piece/part counting. The model features an optional HI6130 (4.3-inch color TFT touchscreen) for operation and setup.

Take the HI6800 For a Test Drive

Featuring dual-port connectivity and an embedded network switch, the HI6800  makes serving up data to both control networks and information networks simple and safe.  Choose from the most popular Industrial Fieldbus protocols for control networks: EtherNet/IP or Modbus TCP/IP; while reaping the benefits of IIoT device-level connectivity though a built-in Webserver. 

The Model HI6800 comes with two Ethernet ports, a microSD card slot, USB-C port, 2 digital outputs, 2 digital inputs, and a single analog scale input. The dual 10/100 Mbps Ethernet ports with integrated network switch are ideal for simultaneously linking the instrument to both control and information networks for monitoring performance, diagnostics, and process statistics. Data from the instrument can be easily served up to the Intranet, Extranet, VPN, and the Internet by utilizing the EtherNet/IP or Modbus TCP/IP communication protocols.

Video on Migrating an HI4050 to the HI6800 Series

SUPERIOR PERFORMANCE
Featuring Hardy’s exclusive WAVERSAVER+®, even in noisy environments with excessive amounts of mechanical vibration, the HI 6800 provides a steady 1:30:000 resolution in oz, lb, ton, g, and kg at 250 updates per second.

SIMPLE SET-UP, CALIBRATION, MAINTENCE & TROUBLESHOOTING 
Use Hardy’s exclusive C2® Second Generation Calibration for automatic system calibration to save hours in commissioning and routine maintenance.  By reading the calibration certificate electronically embedded in the C2® load cell sensor, the scale system can be calibrated with the touch of a button; avoiding time consuming and expensive traditional calibration procedures.

QUICK MAINTENANCE AND TROUBLESHOOTING
Comprehensive diagnostics are displayed for power, network, and weighing function status allowing users to quickly identify faults and solve issues by following on-board help instructions. With INTEGRATED TECHNICIAN®, maintain and troubleshoot the weighing system at the sensor level by diagnosing individual scale components (load cells) without the need to disconnect wiring.  

HI6800 Back

MIMIC FACEPLATE FOR FACTORYTALK VIEW MACHINE EDITION (ME)

The ME FacePlate for the HI6800 is for downloading into a touch screen, typically the PanelView 700 series.  It is designed to "mimic" the look and feel of the HI6800 for ease of calibration with zero, tare and status monitoring.

This FacePlate is factory developed and managed by Hardy and is only available for download from the Hardy website under the Docs and Programs Tab.

  Mimic FacePlate for FactoryTalk View ME

HI6800 Weight Controller
 
Processor:     Dual-core
 
Resolution:    Stable processed weight 1:30,000
                        Internal resolution: 24-bit
 
Update Rate: Processed weight: 250 Hz.
                       Unprocessed weight (A/D conversion rate): up to 4,800 Hz.
 
Modes:          Gross, Net, Count (standard)
                       Rate of Change (optional - Coming Soon)
 
Units of Measure:    Ounce, Pound, Ton, Gram, Kg, Metric Ton
 
Weight Processing:  WAVERSAVER® : .25 Hz to 7.5 Hz
                                   WAVERSAVER+: ADAPTABLE
                                   Averaging: 1 to 255 User-selectable in single increments
 
Calibration Methods:  C2® calibration without test weights
                                       Traditional calibration with test weights
 
Sensor(s): Up to 8 load cells at 350 Ω 
  • Sensor Excitation, 5Vdc
  • Sense, +5 Vdc
  • Signal, -0.3 mV to +15 mV
  • C2® Electronic Calibration
  • Power: 10 watts maximum
  • AC - 90-240 VAC
  • DC – 12-27 VDC (do not exceed 30 VDC)
Operating temperature: -10° to 40°C (14°F to 104°F)
Storage temperature:      -30° to 70°C (-22° to 158°F)
Humidity:                          - 0-90% non-condensing
 
Network Options: Ethernet/IP, Modbus TCP/IP (standard)
Input/Output: Standard – 2 digital Inputs / 2 digital outputs (mappable)
                                           2 inputs (sinking 0-24vdc)
                                           2 outputs (sourcing 0-32vdc@300mA)
Dimensions:  6.15 in L x 3.63 in W  x 3.36 H (156.2 mm x 92.1 mm x 82.8 mm) 
                       - DIN Rail Mounts: Add 0.67 in or 16.9 mm to Width
                       - Connectors: Add 0.44 in or 11.2 mm to Width
HI6130 Touch Screen Display: 7.26 in L x 0.53 in W x 3.26 in H (184.4 mm x 13.3 mm x 82.8 mm)
 
Environmental:  Instrument:  IP-54
                            Display:  IP65 (Type 4/4X).
 
Approvals:   Safety: UL & CUL, CE
                     NTEP
                     EtherNet/IP®:  ODVA Certification Level III
                     UL Hazardous: Class I, Div 2, Groups A, B, C and D; Class II, Div 2, Groups F and G; Class III 
 
Compliance: RoHS3 and Reach
 
Warranty:   Two-year warranty against defects in workmanship 
 
Optional Parts:
0551-0688-01-0:  DIN Rail Mounting Kit for the HI6800 Series
6032-0089-L10FT: 10 ft. Ribbon Cable for HI6130 and HI6150 Displays
6032‐0089‐L4.00:  4-inch Ribbon Cable for HI6130 and HI6150 Displays
HI6130: Panel Mount 4.3-in Touch Screen Display (sold separately from instrument)

Mounting Type

Enclosure

Application

Power Input

Model # - HI6800 copy
Or call 858.278.2900 for assistance

The Hardy Process Toolbox is a set of productivity tools that support industrial weighing functions. Each tool saves time, increases accuracy, improves efficiency, or reduces risk in process weighing applications, including WAVERSAVER® to eliminate vibration, C2® electronic calibration, and Integrated Technician® to name just a few.

The HI 4050 features the following Toolbox technologies:

C2® (or eCAL) Electronic Calibration

The Hardy C2®  (or eCAL as it is known in China) core feature provides quick and easy electronic calibration of a weighing system without the need for heavy test weights.

INTEGRATED TECHNICIAN® Operator Diagnostics

Hardy's INTEGRATED TECHNICIAN (IT) core feature helps you troubleshoot your weighing system and diagnose problems from the front of the instrument or via the PLC. These tests display system weights, voltages, and pass/fail displays to help isolate a problem to the instrument, cabling, or sensors, helping to reduce maintenance costs.

WAVERSAVER® vibration eliminator

Hardy's WAVERSAVER core technology eliminates the effects that surrounding vibration has on the scale weight signal, providing only true data for fast, accurate weight reading.

WAVERSAVER+

A patent pending dynamic algorithm that improves the stability of static weight readings by 3X.

Embedded Web Server

Access your instrument from any computer browser, easing setup and making diagnostics fast and easy. Use the Embedded Web Server to set up all parameters from anywhere on the Ethernet network.

Secure Memory Module Stores Configuration Data

Hardy's Secure Memory Module (SMM) uses a standard SD card to automatically back up critical weighing system data, allowing you to transfer it to another like controller in a few minutes. You can also use the card to easily back up your controller data onto a PC.

Certifications

Datasheets

Manual

Tech Notes

Drawings

Add-On-Profile

Programs and Firmware

Faceplate