Cliquez ici pour en savoir plus !WAVERSAVER+ Options: Variation_thd and Motion_thd
WAVERSAVER+ is a superset of WAVERSAVER that uses two entirely new parameters, Variation_thd (Variation Threshold) and Motion_thd (Motion Threshold). These two parameters add a patent-pending adaptive filtering algorithm to the WAVERSAVER output that provides stability to weight readings of up to 1:30,000.
To configure WAVERSAVER+, set the WAVERSAVER and NumAverages parameters to establish the speed and required accuracy for dynamic weighing. Set the variation_thd to 0.0 and observe the peak to peak variation of the weight value. Then set the variation threshold parameter to be 1.5 times larger than the observed weight variation. Set the motion threshold to 1/3 of the observed peak to peak weight variation.
For example, if the observed weight change is 6, set the variation_thd should be set to 9 (1.5X) and the motion_thd parameter set to 2 (1/3X). Note the weight changes will settle to a 2 increment level.
Weight changes smaller than 1:40,000 will need considerations for environmental protections from air movement forces and additional WAVERSAVER and NumAverages settings.
The default factory setting is 0.0; which turns WAVERSAVER+ OFF.