Cliquez ici pour en savoir plus !On the HI 3030, the Setpoint outputs are the HI2 word. Bit 0 (HI2.0) is for setpoint 1, Bit 1 (HI2.1) is for setpoint 2, etc. These bits indicate that the conditions for that setpoint have been met.
The HFO9 word is the value the setpoint 1 is looking at (i.e. gross weight, net weight, etc). HFO10 is the source for setpoint 2, HFO11 for setpoint 3, etc.
For a list of mapping symbols, click on the link "Click Here for a list of mapping symbols" located on the Mapping Source Page in the browser of the unit.