- des
- Batching & Blending
- Filling, Dispensing & Dosing
- Product Inspection
- Weighing in Hazardous Areas
- Other Solutions
- Connectivity Options
Nouvelles gammes de batterie HIDS !
Cliquez ici pour en savoir plus !The HI 200DNWM has a default output of integer format and a resolution of three decimal places. This cannot be changed in the Series A Device Net modules.
The HI 200DNWM Series B modules have the same default output, but also have the ability to request specific parameter data. You would request data by entering the desired parameter ID number into the scanners' output table. When the data is requested in this manner, the data will be transferred in either integer or floating-point format, based on the Multiplier setting. If this Multiplier setting selects integer format, it also determines the decimal place resolution.
Also see the related answer: