Vous n'avez aucun article dans votre panier.

Nouvelles gammes de batterie HIDS !

Cliquez ici pour en savoir plus !
HISBHC14 - C2® Stainless Steel, Hermetically Sealed Shear Beam Load Cell (500 lbs - 5,000 lbs)

HISBHC14 - C2® Stainless Steel, Hermetically Sealed Shear Beam Load Cell (500 lbs - 5,000 lbs)

Hardy footed load cells are designed to prevent unwanted forces from affecting load cell performance providing an accurate load cell. Optional height adjustable, self aligning rubber feet make it easy to level the load, whether it is a platform scale or a large tank.

Complete Your System

Or call 858.278.2900 for assistance

The HISBHC14 uses a threaded foot design that eliminates the potential for lift-off from the foot. The optional height adjustable, self aligning rubber foot combines excellent load introduction with a low profile design. The height is very easy to adjust through rotation of the foot.

Each sensor comes matched by mV/V/ohm and includes true hermetic sealing, C2® Electronic Calibration, and on-board electronic certs. With IP68/ IP69K, these load cells provide a high degree of ingress protection.

Features

  • C2 Electronic Datasheets for EASY Electronic Calibration
  • Complete Hermetic Sealing
  • Optional Compatible Height Adjustable Rubber Foot (HIHARF6)
  • Matched mmV/V/Ω load cells

User Benefits at a Glance

  • Perfect combination of advanced features and economy for OEMs and System Integrators
  • C2® Electronic Calibration
  • Industry Standard Load Cell Form factor allows for easy upgrade of existing systems to utilize C2®
  • IP68/IP69K ingress protection according to EN 60 529

 

SPECIFICATIONS

Units

HI SBHC14

Maximum Capacity (Emax)

lbs

500 / 1000 / 2500 / 5000

Max number verification intervals

nmax

3000

Min load cell verification interval

vmin

Emax / 11500

Combined Error

%RO

± 0.0200

Non-Linearity

%RO

± 0.0166

Hysteresis

%RO

± 0.0166

Creep error (30 Minutes) / DR

%RO

± 0.0166

Temperature effect on min dead load ouput

%RO/10°C

± 0.0122

Temperature effect on sensitivity

%RO/10°C

± 0.0100

Rated Output (RO)

mV/V

2 ± 0.1%

Calibration in mV/V/Ω

 

Matched

Zero Balance

%RO

±5

Excitation Voltage

V

5 to 15

Input Resistance

W

1100 ± 50

Output Resistance

W

1000 ± 2

Insulation resistance (100VDC)

MW

≥ 5000

Load Cell Safe Load Limit

%Emax

200

Load Cell Ultimate Load Limit

%Emax

300

Load Cell Safe Side Load

%Emax

100

Compensated Temp Range

°C

-10 …+40

Operating Temp Range

°C

-40…+80

Load Cell Material (metallurgy

 

Stainless Steel 17-4PH (1.4548)

Sealing

 

Complete Hermetic Sealing Glass to Metal Header

Protection according to EN 60 529

 

IP68 (up to 2m water depth) / IP69k

Cable Length

ft

20

HIHARF6 optional foot Optional foot HIHARF6

Capacity

Model # - HISBHC14 copy
Or call 858.278.2900 for assistance

The Hardy Process Toolbox is a set of productivity tools that support industrial weighing functions. Each tool saves time, increases accuracy, improves efficiency, or reduces risk in process weighing applications, including C2® electronic calibration, and Integrated Technician® to name just a few.

Hardy load cells support the following Hardy Process Toolbox functions when coupled with a Hardy Instrument and Hardy C2® cable.

C2® (or eCAL) Electronic Calibration

The Hardy C2® (or eCAL as it is known in China) core feature provides quick and easy electronic calibration of a weighing system without the need for heavy test weights.

INTEGRATED TECHNICIAN® Operator Diagnostics

Hardy's INTEGRATED TECHNICIAN (IT) core feature helps you troubleshoot your weighing system and diagnose problems from the front of the instrument or via the PLC. These tests display system weights, voltages, and pass/fail displays to help isolate a problem to the instrument, cabling, or sensors, helping to reduce maintenance costs.

Certifications

Datasheets

Drawings