- Description
- Specifications
- Configuration
- Process Toolbox
- plugin.toolkit.productdownloads.documentdownload.heading
The HISB05 is a stainless steel, mV/V and mV/V/ohm matched load sensor with C2® Electronic Calibration capabilities, and has the ability to deliver customer savings for applications that do not require hermetic sealing. With the IP67 rating and hazardous FM approval, this durable workhorse pairs with a wide variety of of mounts to deliver consistent shear beam performance.
SPECIFICATIONS |
HI SB05* |
Capacity lbs |
1125/2250/4500/11250/22500 lbs |
Capacity kg |
510/1020/2040/5102/10206 kg |
Rated Output (ES) |
2±0.002mV/V |
Non-Linearity |
<±0.0166 % R.O.* |
Hysteresis |
<±0.0166 % R.O.* |
Zero Balance |
<±5.0 % R.O.* |
Combined Error |
<±0.02 % R.O.%* |
Creep @ 30 Min. |
<±0.0166 % R.O.* |
Temp Effect Output |
±0.0127 % R.O./C* |
Temp Effect Sensitivity |
±0.010 % R.O./C* |
Input Resistance |
1100±50 ohm |
Output Resistance |
1000 ± 2 ohm |
Insulation Resistance |
≥5000 Mohm |
Excitation |
5 - 15 vdc |
Safe Load Limit |
200 % Emax |
Ultimate Load |
300 % Emax |
Safe Side Load |
50% Emax |
Approvals |
NTEP Class III |
Hazardous |
FM IS Class I, Div I |
Protection EN 60 629 |
IP67 |
Warranty |
Two years |
* HI SBH05 in 22.5Llb capacity ONLY |
The Hardy Process Toolbox is a set of productivity tools that support industrial weighing functions. Each tool saves time, increases accuracy, improves efficiency, or reduces risk in process weighing applications, including C2® electronic calibration, and Integrated Technician® to name just a few.
Hardy load cells support the following Hardy Process Toolbox functions when coupled with a Hardy Instrument and Hardy C2® cable.
C2® (or eCAL) Electronic Calibration
The Hardy C2® (or eCAL as it is known in China) core feature provides quick and easy electronic calibration of a weighing system without the need for heavy test weights.
INTEGRATED TECHNICIAN® Operator Diagnostics
Hardy's INTEGRATED TECHNICIAN (IT) core feature helps you troubleshoot your weighing system and diagnose problems from the front of the instrument or via the PLC. These tests display system weights, voltages, and pass/fail displays to help isolate a problem to the instrument, cabling, or sensors, helping to reduce maintenance costs.