Hardy Process Solutions is committed to providing customer value through the configurability of its sensor line. For compression applications between 1125 lb and 22,500 lb (.5 mt and 10 mt), Hardy offers accurte shear beam load cells for demanding mounting situations with side forces (~50% Emax) and anti-uplift requirements

Or call 858.278.2900 for assistance

The Hardy HILPS05 ADVANTAGE® Lite Series sliding load cell system consists of stainless steel, mV/V and mV/V/ohm matched  HISB05 load sensors and mounts with an IP67 rating and C2® electronic calibration capabilities. The load sensor combined with the bumper, slider, fixed mounting configuration offers durable workhorse performance, along with best-in-class protection from liftoff (6.6 -15.2Klbs) and side forces, and best-in-class accuracy in  vibration installations. The bumper slider fixed mount is perfect for agitated vessels, vibratory feeders, and wind-loaded tanks.  With hazardous FM approval, this industrial load cell system deliver consistent shear beam performance.

SPECIFICATIONS HIHLPS Mounts

Load Point with Stainless Hardware (-43) or zinc plated Hardware (-45).  Shipping Weight approx.10-35 lbs. for Mounts, and 4-17 lbs. for each Sensor.  

A vessel with 3 legs will require 1 each fixed (F), bumper (B) & slider (S) assy.

A vessel with 4 legs will require 1 each fixed (F), bumper (B) & 2 each slider (S) assy.

Load points can be ordered as a 3 or 4 load cell system rather than ordering individual components.

lbs         mt    FIXED    BUMPER    SLIDER    Part #
1,125    0.5     F             B                   S         HILPS05-1125-4__
2.25K    1        F             B                   S         HILPS05-2.25K-4___
4.5K      2        F             B                   S         HILPS05-4.5K-4___
11.25K   5       F             B                   S         HILPS05-11.25K-4___
22.5K   10       F             B                   S         HILPS05-22.5K-4___

CAPACITY MODEL#  3 POINT LOAD CELL SYSTEMS
lbs               mt          Part #
3,375           1.5          HI3S05-3375-4__
6.75K           3.1          HI3S05-6.75K-4__
13.5K           6.1          HI3S05-13.5K-4__
33.75K        15.3         HI3S05-33.75K-4__
67.5K          30.6         HI3S05-67.5K-4__

CAPACITY MODEL# 4 POINT LOAD CELL SYSTEMS
lbs              mt            Part #
4.5K            2.0            HI4S05-4.5K-4__
9K               4.1            HI4S05-9K-4__
18K             8.2            HI4S05-18K-4__
45K            20.4           HI4S05-45K-4__
90K            40.8           HI4S05-90K-4__

SPECIFICATIONS HISB05*

Capacity lbs        1125/2250/4500/11250/22500 lbs

Capacity kg        510/1020/2040/5102/10206 kg

Rated Output (ES)    2±0.002mV/V

Non-Linearity        <±0.0166 % R.O.*

Hysteresis        <±0.0166 % R.O.*

Zero Balance        <±5.0 % R.O.*

Combined Error        <±0.02 % R.O.%*

Creep @ 30 Min.        <±0.0166 % R.O.*

Temp Effect Output    ±0.0127 % R.O./C*

Temp Effect Sensitivity    ±0.010 % R.O./C*

Input Resistance    1100±50 ohm
  
Output Resistance      1000 ± 2 ohm

Insulation Resistance    ≥5000 Mohm

Excitation        5 - 15 vdc

Safe Load Limit        200 % Emax

Ultimate Load        300 % Emax

Safe Side Load         50% Emax

Approvals        NTEP Class III, RoHS 3, REACH

Hazardous         FM IS Class I, Div I

Protection EN 60 629    IP67

Warranty

Two years

* HI SBH05 in 22.5Llb capacity ONLY
• Non-Linearity ±0.0400% R.O
• Hysteresis ±0.0400% R.O.
• Combined Error ±0.0500% R.O.
• Creep error @30 Min.±0.0600% R.O.
• Temp Effect Ouput ±0.0400% R.O./10°C
• Temp Effect Sensitivity +0.0200% R.O./10°C

The Hardy Process Toolbox is a set of productivity tools that support industrial weighing functions. Each tool saves time, increases accuracy, improves efficiency, or reduces risk in process weighing applications, including C2® electronic calibration, and Integrated Technician® to name just a few.

Hardy load cells support the following Hardy Process Toolbox functions when coupled with a Hardy Instrument and Hardy C2® cable.

C2® (or eCAL) Electronic Calibration

The Hardy C2® (or eCAL as it is known in China) core feature provides quick and easy electronic calibration of a weighing system without the need for heavy test weights.

INTEGRATED TECHNICIAN® Operator Diagnostics

Hardy's INTEGRATED TECHNICIAN (IT) core feature helps you troubleshoot your weighing system and diagnose problems from the front of the instrument or via the PLC. These tests display system weights, voltages, and pass/fail displays to help isolate a problem to the instrument, cabling, or sensors, helping to reduce maintenance costs.

Certifications

Datasheets

Manual

Drawings