Hardy’s new HIDS Drum scales are accurate, rugged and reliable floor scales that provide value and flexibility while optimized for weighing industrial drums. They come with a built-in 1.5" access ramp designed for easy loading and unloading of drums.

Or call 858.278.2900 for assistance

Available in two sizes from 30 x 30 inch to 36 x 36 inches in 500, 1,500 and 3,000 lb capacities.

EASY WASHDOWN & INSTALLATION
HIDS Drum Scales are designed and built for industrial environments. Incredibly easy to install and use; just level the deck, attach the included cable to AC power, calibrate (if a C2® compatible instrument, set your reference), verify and begin weighing.

C2® ELECTRONIC CALIBRATION
Used with a Hardy weight processor or controller, C2 enables fast, accurate, electronic calibration without test weights. The C2 system reduces downtime for installation or repairs and eliminates test weight related injuries. A small weight verifies calibration.

INTEGRATED TECHNICIAN®
Each scale has built-in INTEGRATED TECHNICIAN (IT) circuitry in the integrated junction box. Coupled with a Hardy controller or instrument, the scale provides diagnostic and troubleshooting tools that read individual weights and voltages from each load cell to aid you in isolating problems and ensure the integrity of your scale system.

STAINLESS STEEL LOAD SENSORS
The heart of any scale is the load sensors. All HIDS Scales come standard with four matched stainless steel, IP67 HISLB load cells calibrated for mV/V and mV/V/ohm. This eliminates the need for corner adjustment and potentiometers in the junction box, allowing a sensor to be replaced without calibration. With a threaded hole into which the load cell foot is attached, the load is applied at a precise location to provide an accurate reading, weighment after weighment.

RUGGED, LOW PROFILE DESIGN
With a deck height of only 1.5" inches and 100% end loading, these floor scales enable easy, slide on/slide off access for easy drum handling and three raised sides to ensure the drum is centered on the Scale.

SERVICE BY DESIGN
Along with C2 and INTEGRATED TECHNICIAN, HIDS Drum Scales feature a top access plate for quick and easy access to the Hardy 6011 Summing Card, ensuring that general maintenance is easier and more time-efficient.

HIDS Drum Scale load tested to 200% capacity.
The HIDS Drum Scale was load tested to 200% Capacity using three1,000 lbs test weights on a 1,500 lbs scale.  

 

HIDS Drum Scale Specifications

PlatformHIDS Drum Scale
• Safety tread deck or smooth deck
Deck Height
• 1.5 inches (3.8 cm) with adjustable feet
Overload Capacity
• 200% of rated scale capacity
End Loading
• 100% of rated scale capacity
Cable Length
• Platform to Instrument - 20 feet
(for longer cable lengths, contact the Factory)
Construction
• Painted Carbon Steel with Alkyd Enamel Paint
• 2 to 4 mil top coat
Load Sensors
• HISLB C2® 17-4PH stainless steel
• IP67 Environmentally Sealed
Summing Card
• NEMA 4X Hardy HI6011 Summing Card
Power Rating Load Cells
• 5 VDC, Class 2 source, max. 50 mA
Hardy 6011IT Summing Card
• 4 Individual load sensor terminal blocks with
integrated cable glands
• INTEGRATED TECHNICIAN® circuitry
Scale Excitation
• 5vdc +/-5%
Accuracy
• Combined Error: 0.02%
• Repeatibility: 0.01%
Certifications
• CE • RoHS and REACH Compliant
Warranty
• Two year limited warranty
Shipping Weight
176 lbs/80 kgs

HISLB Load Cell Specifications 
Maximum Capacity (Emax) lbs
200 / 500 / 1,000 / 2,500 / 5,000
Maximum Capacity (Emax) kgs
91 / 227 / 454 / 1,134 / 2,268
Accuracy Class III
Max number verification intervals nmax
3000
Min load cell verification interval vmin
Emax / 11500
Combined Error %RO
± 0.0200
Non-Linearity %RO
± 0.0166
Hysteresis %RO
± 0.0166
Creep error (30 Minutes) / DR %RO
± 0.0166
Temperature effect on min dead load ouput %RO/10°C
± 0.0122
Temperature effect on sensitivity %RO/10°C
± 0.0100
Rated Output (RO) mV/V
2 ± 0.1%
Zero Balance %RO
± 5
Excitation Voltage V
5-15
Input Resistance Ω
1100 ± 50
Output Resistance Ω
1,000 ± 2
Insulation resistance (100VDC) MΩ
≥ 5000
Load Cell Safe Load Limit %Emax
200
Load Cell Ultimate Load Limit %Emax
300
Load Cell Safe Side Load %Emax
100
Compensated Temperature Range °C
-10 …±40
Operating Temperature Range °C
-40…±80
Load Cell Material
Stainless Steel 17-4PH (1.4548)
Sealing
Environmentally Sealed
Protection according to EN 60 529
IP67
Cable Length in ft
10 ft
Manufacturer's Warranty
Two Years

Capacity

Platform Size

Deck Plate

Model # - HIDS copy
Or call 858.278.2900 for assistance

The Hardy Process Toolbox is a set of productivity tools that support industrial weighing functions. Each tool saves time, increases accuracy, improves efficiency, or reduces risk in process weighing applications, including WAVERSAVER® to eliminate vibration, C2® electronic calibration, and Integrated Technician® to name just a few.

The Hardy Drum Scales feature the following Toolbox technologies:

C2® Electronic Calibration

The Hardy C2® (or eCAL as it is known in China) core feature provides quick and easy electronic calibration of a weighing system without the need for heavy test weights. Unlike calibration with test weights, all the live weight on the scale does not have to be removed and heavy test weights do not have to be repeatedly put on and off the scale. As soon as your scale system is installed, it can be C2 or eCAL calibrated, and proper scale installation verified. The result is a calibration that is easier, quicker, safer, and typically more accurate.

WAVERSAVER® Vibration Eliminator

Hardy's WAVERSAVER core technology eliminates the effects that surrounding vibration has on the scale weight signal, providing only true data for fast, accurate weight reading.

Embedded Web Server

Access your instrument from any computer browser, easing setup and making diagnostics fast and easy. Use the Embedded Web Server to set up all parameters from anywhere on the Ethernet network.

Secure Memory Module Stores Configuration Data

Hardy's Secure Memory Module (SMM) uses a standard SD card to automatically back up critical weighing system data, allowing you to transfer it to another like controller in a few minutes. You can also use the card to easily back up your controller data onto a PC.

Datasheets

Drawings